A researcher at the Belgian Nuclear Research Centre who is involved in nuclear emergency planning is looking for methods to fix radioactive material to the soil after it has been spread into the environment after an incident. They know a similar tech...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
5/24/2013 9:17:04 AM
Last Updated:
6/4/2013 12:22:34 PM
# of Solutions:
6
|
|
Good afternoon, I am trying to find samples/examples of site characterization plans for nuclear facilities. Not a project specific plan but a characterization plan/procedure for an entire site such as; ORNL, Rocky Flats, Los Alamos, Portsmouth Gaseou...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
11/7/2012 10:20:55 AM
Last Updated:
11/16/2012 1:25:34 PM
# of Solutions:
4
|
|
Looking for information on vacuum cleaners (HEPA) high value units, scabbling tools, nibblers and the chemical decon foam process....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/20/2008 11:53:55 AM
Last Updated:
3/11/2011 3:48:24 PM
# of Solutions:
4
|
|
FH Groundwater RadCon visited the Center looking for a means of passing material out of well casing jack stand containment....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/21/2008 2:24:56 AM
Last Updated:
8/28/2008 10:39:33 AM
# of Solutions:
3
|
|
Looking for options for drilling multiple holes for Hilti bolts in contaminated outside walls. The contamination has been painted over. The original plan was to accomplish the drilling in a glovebag....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/9/2008 10:25:11 PM
Last Updated:
3/17/2008 1:13:38 PM
# of Solutions:
3
|
|
Looking for a means of fixing radioactive contamination to a metal surface....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
3/11/2008 1:03:21 PM
Last Updated:
3/17/2008 1:29:20 PM
# of Solutions:
3
|
|
I will be talking about some of the SRNL technology developments, in particular underwater grout. But there is also interest in decontamination technology, especially anything that does not involve concrete removal, and remote inspection tools, both ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
11/15/2012 10:01:26 AM
Last Updated:
11/27/2012 10:32:31 AM
# of Solutions:
3
|
|
T-Plant has a shielding issue on one of the process skids as follows,
T-Plant has a couple of small hoses that come up through a deck penetration and travel across the deck. There is a concern that during the ORR that an operator at a control panel ...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/10/2008 11:49:28 AM
Last Updated:
3/17/2008 2:17:00 PM
# of Solutions:
2
|
|
Concerning methods to decontaminate the metal beds of trucks. Grinding and wire brushing were unsuccessful. ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
3/11/2008 12:46:44 AM
Last Updated:
3/17/2008 2:22:49 PM
# of Solutions:
2
|
|
Looking for a tool that could be used to cut an ~ 8" diameter twisted sleeve during removal of a standard waste box from a containment enclosure. Plan is to section gloveboxes and other components and lower the waste/debris into a waste box. When fu...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/7/2008 12:57:30 PM
Last Updated:
3/20/2008 9:48:18 AM
# of Solutions:
2
|
|
Looking for a communication system for personnel wearing masks while working....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/7/2008 2:25:38 PM
Last Updated:
3/17/2008 4:22:29 PM
# of Solutions:
2
|
|
In need of a crusher that will flatten piping up to a 4" diameter....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/9/2008 5:42:37 PM
Last Updated:
3/17/2008 4:24:12 PM
# of Solutions:
2
|
|
Looking for additional protection for workers. Seeking a longer length than the normal length PPE rubber glove....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/10/2008 12:45:41 PM
Last Updated:
3/17/2008 4:28:47 PM
# of Solutions:
2
|
|
Concerning the decontamination of hot cells, please discuss techniques available that don't create a lot of liquid....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/21/2008 3:12:16 PM
Last Updated:
3/17/2008 2:10:04 PM
# of Solutions:
2
|
|
PFP OPs called and discussed a job they have a size-reducing small diameter stainless steel tubing in a glove box. Original plan was to cut and cap the tubing but decided on crimping and then cutting...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/21/2008 12:44:07 PM
Last Updated:
2/27/2008 2:51:31 PM
# of Solutions:
2
|
|
Looking for information on commercial drum lids that can be used to collect debris before it reaches the vacuum cleaner....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/21/2008 12:59:59 PM
Last Updated:
3/19/2008 4:32:46 PM
# of Solutions:
1
|
|
Looking for a pump (UL approved) to pump personnel showers at Building 219 asbestos removal job. See www.randolphaustin.com ...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/21/2008 1:20:14 PM
Last Updated:
3/2/2008 7:47:14 AM
# of Solutions:
1
|
|
Looking for rock stoppers (ventilation drum lids) and information on HEPA filtered vacuum cleaners....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/21/2008 1:25:33 PM
Last Updated:
3/19/2008 4:45:19 PM
# of Solutions:
1
|
|
Request for information on controlled demolition techniques ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/21/2008 1:36:39 PM
Last Updated:
3/20/2008 10:15:31 AM
# of Solutions:
1
|
|
Looking for tooling to cut up staging planks in a very small restricted space....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/21/2008 1:55:56 PM
Last Updated:
2/28/2008 10:23:19 AM
# of Solutions:
1
|
|
Looking for a means of sealing a grouted surface, so that during work, no radioactive contamination is transferred to hoses and other material coming in contact with the deck. ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/21/2008 2:37:11 PM
Last Updated:
2/28/2008 10:24:30 AM
# of Solutions:
1
|
|
Help in finding a "tree pruner" that could be used to cut 2-3" hoses underwater in the K Basin fuel pools....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/21/2008 2:47:19 PM
Last Updated:
2/28/2008 10:25:35 AM
# of Solutions:
1
|
|
A well-written report with many photos showing what happens when foam is injected into piping and other components at Oak Ridge National Labs....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/7/2008 11:32:26 AM
Last Updated:
5/5/2009 10:31:27 AM
# of Solutions:
1
|
|
We are looking at methods to size-reduce components underwater at a fuel pool at Brookhaven Lab....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
3/7/2008 12:14:38 PM
Last Updated:
3/20/2008 7:46:37 AM
# of Solutions:
1
|
|
K-Basins RadCon visited the Center looking for a method of draining buoyancy cylinders on long handled basin tools. The cylinders have to be opened to ensure all liquid is removed. K-Basins have tried to drill holes into the stainless steel cylinde...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/21/2008 1:33:23 AM
Last Updated:
2/28/2008 10:26:39 AM
# of Solutions:
1
|
|
Want to apply a long lasting, penetrating suppressant during excavation of a mound of dirt in the 618-2 burial ground. Asking about any "tracer" to add to make it easier to see where the fixative had been applied. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/21/2008 12:08:06 PM
Last Updated:
3/2/2008 8:02:09 AM
# of Solutions:
1
|
|
Information regarding old Hanford photos and documents....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/21/2008 12:26:07 PM
Last Updated:
2/28/2008 10:31:24 AM
# of Solutions:
1
|
|
PFP Engineering visited the Center looking for information on a wall climbing machine....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/21/2008 12:36:22 PM
Last Updated:
3/2/2008 8:04:16 AM
# of Solutions:
1
|
|
Looking for advice on the best fixative to coat 250,000 sq ft of floor space that has Tc-99 contamination. Would prefer a product that is cost effective and will not be washed off with water. In addition, minimum protective equipment is prefered when...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
3/10/2008 2:10:58 PM
Last Updated:
3/17/2008 4:42:54 PM
# of Solutions:
1
|
|
Looking for tools to size reduce a highly contaminated 70' long drill string in order to remove it and place it in a burial box....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/10/2008 2:25:38 PM
Last Updated:
3/17/2008 4:56:12 PM
# of Solutions:
1
|
|
A group is demolishing buildings and estimates the work could be accomplished faster if contaminated piping in the building could be left in place and removed as part of the debris after the building is demolished. Please advise on possible methods ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/10/2008 4:32:31 PM
Last Updated:
3/17/2008 5:07:34 PM
# of Solutions:
1
|
|
Need a small blade plunging cutter for cutting pipes and valves.
Please provide vendor information. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/10/2008 4:41:50 PM
Last Updated:
3/19/2008 1:44:33 PM
# of Solutions:
1
|
|
Looking for information regarding filling pipes with expandable foam prior to cutting. A 6" diameter pipe has 5 internal lines. It is desired to stop the lines from flopping around during the cutting process through use of foam. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/10/2008 11:57:44 PM
Last Updated:
3/19/2008 2:20:00 PM
# of Solutions:
1
|
|
Looking for fixatives that can be used to seal openings and crevices in single-shell valve pit covers....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/11/2008 12:10:48 AM
Last Updated:
5/5/2009 10:32:10 AM
# of Solutions:
1
|
|
In need of a 4' high roll-around rack that can be used to hang temporary shielding....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/9/2008 6:01:53 PM
Last Updated:
3/17/2008 5:08:50 PM
# of Solutions:
1
|
|
Concerning an aerosol fogging solution sold by Encapsulation Technologies. The ETGS Invisible Blue fixative was applied in a contamination area. It was not possible to see any fluorescence from the fixative with a black light after it was applied. ...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
3/7/2008 1:14:37 PM
Last Updated:
3/19/2008 1:07:13 PM
# of Solutions:
1
|
|
Information concerning methods about determining the presence of liquids in piping without hot tapping....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/9/2008 10:40:23 PM
Last Updated:
3/17/2008 5:14:15 PM
# of Solutions:
1
|
|
Requesting information on a lighted video probe or bore scope. Equipment needs to be lowered 40' down a pipe and be able to record on videotape....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/9/2008 10:56:14 PM
Last Updated:
3/17/2008 5:30:05 PM
# of Solutions:
1
|
|
Requesting information on what a lead wool shielding bat is equivalent to in sheet lead....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/9/2008 11:17:41 PM
Last Updated:
3/19/2008 10:56:43 AM
# of Solutions:
1
|
|
Looking for information on a lifting gear that can be used on 55 gallon drums using a forklift....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/9/2008 11:28:12 PM
Last Updated:
3/19/2008 11:38:04 AM
# of Solutions:
1
|
|
Looking for information on temporary shielding and portable shielding racks....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/9/2008 11:45:51 PM
Last Updated:
3/19/2008 11:54:27 AM
# of Solutions:
1
|
|
Information regarding a pipe shear that maintains the roundness of the pipe. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/10/2008 1:10:03 AM
Last Updated:
3/19/2008 12:06:07 PM
# of Solutions:
1
|
|
Requesting help in finding a better degreaser than the "Simple Green" being used at U-Plant for D&D Work....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
3/10/2008 1:32:56 AM
Last Updated:
3/19/2008 12:57:05 PM
# of Solutions:
1
|
|
A large facility that is highly contaminated has paint flaking off the walls, ceiling and floors. The lower portion of the building is concrete with two large towers that are made of steel. Please advise with regards to suitable fixatives.
...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
3/11/2008 1:40:56 PM
Last Updated:
3/26/2008 9:44:46 AM
# of Solutions:
1
|
|
Looking for mechanical cutters for umbilical sleeve cuts. Please provide vendor(s)....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/11/2008 2:02:48 PM
Last Updated:
3/19/2008 2:39:06 PM
# of Solutions:
1
|
|
Savannah River Site SRS has an incinerator which the interior is a High Contamination Area. It is lined with bricks "like a fireplace" and has residual ash. SRS needs expertise in selecting a fixative to fix the residual ash and contaminated brick. ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
3/11/2008 2:24:08 PM
Last Updated:
3/19/2008 2:44:38 PM
# of Solutions:
1
|
|
I am looking for a device to secure drums to a table in the upright position...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
3/11/2008 3:12:27 PM
Last Updated:
3/19/2008 2:47:00 PM
# of Solutions:
1
|
|
I would like to get information on the EZ-Reacher Extension Tool. I have to remove a small source from a lead pig and then replace it. Also I am looking for info on a grab sampler that can be used to sample a tank that is about 15' deep. ...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
3/11/2008 3:59:53 PM
Last Updated:
3/19/2008 11:36:31 AM
# of Solutions:
1
|
|
We are looking for providers of FR disposable PPE suits...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/11/2008 6:17:37 PM
Last Updated:
3/19/2008 2:49:36 PM
# of Solutions:
1
|
|
I am looking for methods to cut out a welded tank manway with tools that do not create "hot work"...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
3/12/2008 12:26:48 AM
Last Updated:
3/19/2008 2:53:02 PM
# of Solutions:
1
|
|
I am looking for info on the D&D of graphite reactors. We have a problem with the PBS application, in that it bubbled and was not drying evenly...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/12/2008 12:36:53 AM
Last Updated:
3/17/2008 1:53:06 PM
# of Solutions:
1
|
|
I am looking for a powder like substance that is used to test ventilation flow....
Category : Deactivation & Decommissioning > Characterization
|
Entered:
3/12/2008 1:00:57 AM
Last Updated:
3/19/2008 3:02:14 PM
# of Solutions:
1
|
|
Do you have any information or documents related to decontamination and surveying of embedded and buried piping? ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
3/12/2008 1:10:17 AM
Last Updated:
3/19/2008 4:11:52 PM
# of Solutions:
1
|
|
We are looking for a fixative to seal a sump in an old Silo at 100N. We had originally thought to use ABC, a fixative that has been used on site by insulators for control of asbestos material...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
3/12/2008 1:19:50 AM
Last Updated:
3/19/2008 4:13:26 PM
# of Solutions:
1
|
|
I am looking for information on leaded rubber gloves and other products...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/12/2008 1:26:15 AM
Last Updated:
3/19/2008 4:14:48 PM
# of Solutions:
1
|
|
What is D&D work?...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
3/12/2008 1:54:27 AM
Last Updated:
3/19/2008 4:15:47 PM
# of Solutions:
1
|
|
I am looking for information on containments that can be inflated to make them easier to install....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/12/2008 2:05:22 AM
Last Updated:
3/19/2008 4:27:45 PM
# of Solutions:
1
|
|
Hi, I am currently working on the stacks demolition process for all the chimneys located at the ORNL. I have been asked by my mentor to search for a conceptual technology that could be applied to this procedure. The first step set on my investigation...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
6/11/2008 2:30:27 PM
Last Updated:
6/26/2008 11:37:45 AM
# of Solutions:
1
|
|
Could you please help identify the best fixative/coating products to apply to the exterior of a corrugated metal building that has both rust and flaking paint? We plan to test at least 3 products and the fixative/coating would need to last until D&D ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
6/23/2008 2:55:52 PM
Last Updated:
7/7/2008 4:02:54 PM
# of Solutions:
1
|
|
I am looking for means, methods, and a list of subcontactors for beryllium decontamination....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
7/14/2008 5:33:56 PM
Last Updated:
7/21/2008 2:41:03 PM
# of Solutions:
1
|
|
I am a D&D Engineer looking for a protective sleeve for our GE Inspection Technologies videoprobe. We need to look 3' inside a component and don't want to contaminate our unit....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/5/2009 1:30:47 PM
Last Updated:
4/16/2009 3:44:04 PM
# of Solutions:
1
|
|
LLNL is currently working on a project and need advice on controlling airborne contamination should a radioactive device be exploded in New York City Subway Tunnels. ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/6/2009 10:24:11 AM
Last Updated:
4/16/2009 4:19:12 PM
# of Solutions:
1
|
|
I would like more information about “ULPA” filters, We have had several new vacuums at Hanford with ULPA filters rather than the standard HEPA filters....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/16/2009 11:17:49 AM
Last Updated:
4/16/2009 4:17:32 PM
# of Solutions:
1
|
|
200LEF planner needs advice on how to handle painting over fixed contamination. ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/16/2009 11:28:41 AM
Last Updated:
4/16/2009 4:25:43 PM
# of Solutions:
1
|
|
Fluor personnel working on the South Texas Project nuclear plant turbine building needs information regarding which companies sell concrete that is mixed with products to make it a better shielding material....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/16/2009 11:37:14 AM
Last Updated:
4/16/2009 4:28:11 PM
# of Solutions:
1
|
|
A Washington River Protection Solutions (WRPS) operator is looking for suggestions on how to remove a small area of contaminated paint. ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/16/2009 11:42:35 AM
Last Updated:
4/16/2009 3:54:36 PM
# of Solutions:
1
|
|
I would like to know information about misting equipment used on track hoes
and inside tanks....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/16/2009 11:54:47 AM
Last Updated:
4/16/2009 4:29:24 PM
# of Solutions:
1
|
|
I am looking for articles and reports that detail recent D&D of hot cells....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/24/2009 12:14:13 PM
Last Updated:
3/26/2009 10:26:19 AM
# of Solutions:
1
|
|
A recent Hanford ALARA newsletter discussed the application of fixatives in tank pits using a "whirly" nozzle (October 27 to November 7, 2008). ORNL considered the use of this type of nozzle to spray fixatives inside a hotcell but did not have any in...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
4/1/2009 2:08:40 PM
Last Updated:
5/5/2009 4:29:14 PM
# of Solutions:
1
|
|
I am looking for equipment to help suppress airborne contamination in a refueling floor, do you have any information on misting equipment vendors? ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
4/1/2009 3:07:57 PM
Last Updated:
4/16/2009 4:32:51 PM
# of Solutions:
1
|
|
FIU is performing a study to identify technologies used to decontaminate concrete surfaces. Does the ALARA Center have a list of technologies or other resources for concrete decontamination? ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
4/15/2009 10:03:23 AM
Last Updated:
5/5/2009 10:54:45 AM
# of Solutions:
1
|
|
I am looking for information about fall protection companies. Can you recommend a few?...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
6/8/2009 2:01:13 PM
Last Updated:
8/26/2009 3:51:41 PM
# of Solutions:
1
|
|
I am looking for products to decontaminate or fix contamination on stainless steel. ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
7/27/2009 11:47:26 AM
Last Updated:
9/14/2009 9:49:52 AM
# of Solutions:
1
|
|
I am interested in finding a product that can be used to decontaminate toxic metals...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
8/24/2009 2:46:13 PM
Last Updated:
9/14/2009 9:51:37 AM
# of Solutions:
1
|
|
Our company has a concern about our workers cutting themselves on sharp edges while moving equipment. We are interested in purchasing some cut and puncture resistant gloves. Could you provide any good vendors?...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
8/24/2009 2:57:49 PM
Last Updated:
9/14/2009 9:56:32 AM
# of Solutions:
1
|
|
I am looking for fixatives and remote coating systems that could be used to remotely coat the inside of a hot cell...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
10/12/2009 10:50:50 AM
Last Updated:
1/13/2010 1:10:45 PM
# of Solutions:
1
|
|
I would like to request help in obtaining a shielded container for high level waste for an upcoming HEPA filter replacement....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
12/7/2009 10:16:49 AM
Last Updated:
1/13/2010 1:11:33 PM
# of Solutions:
1
|
|
I am interested in applying fixatives in hard to access areas. Can you suggest any technologies we can consider for this specific need?...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
1/4/2010 10:56:48 AM
Last Updated:
1/13/2010 1:09:07 PM
# of Solutions:
1
|
|
Lawrence Livermore National Laboratory would like to obtain several ideas to remove potentially radiologically contaminated asbestos floor tiles. They are considering “Outside the Box” techniques for removing contaminated asbestos tile. Once suggest...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/26/2010 10:56:55 AM
Last Updated:
3/24/2010 1:15:25 PM
# of Solutions:
1
|
|
I am looking for cut resistant gloves that could be worn while working in an asbestos glovebag. The glove must allow the workers to maintain enough dexterity to perform asbestos removal and still protect them from cuts. ...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/29/2010 1:32:45 PM
Last Updated:
6/15/2010 12:24:07 PM
# of Solutions:
1
|
|
Savannah River Site is interested in obtaining vendor information for radioactive waste soft packaging. Can you recommend any vendor?...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/29/2010 1:38:17 PM
Last Updated:
6/15/2010 12:25:44 PM
# of Solutions:
1
|
|
Los Alamos Radiological Control is considering purchasing a portable decontamination trailer, can anyone provide information about Tank Farm’s mobile decontamination trailer?...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
4/9/2010 11:33:23 AM
Last Updated:
6/15/2010 12:26:41 PM
# of Solutions:
1
|
|
A Washington River Protection Solutions radiological engineer is looking for strippable paints that could be used to decontaminate a valve pit. The valve pit’s coating bubbled and is in need of repair. The draft plan is to remotely scrape the coati...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
9/27/2010 2:17:52 PM
Last Updated:
3/11/2011 4:04:38 PM
# of Solutions:
1
|
|
I am looking for tools that could be used to cut plastic sleeving (umbilical twisted seals, horsetails, etc.) from gloveboxes or glovebags when shears are no longer effective due to the size of the seal. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
9/27/2010 2:25:21 PM
Last Updated:
9/27/2010 2:30:56 PM
# of Solutions:
1
|
|
We need to determine how to make an adaptor to connect a portable HEPA unit to a filter bank sample port. The portable HEPA is necessary to prevent contamination from being blown back into a clean area during maintenance and testing. Is there a meth...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
9/27/2010 2:37:26 PM
Last Updated:
9/27/2010 2:49:11 PM
# of Solutions:
1
|
|
We are looking for ideas to cut up a stainless steel slab tank 18 to 21 feet long, three and a half feet high, and four and a half inches thick. Our initial plan is to use fixatives inside the tank and cut the tank into smaller more manageable piece...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
9/27/2010 2:42:29 PM
Last Updated:
9/27/2010 2:46:42 PM
# of Solutions:
1
|
|
Decom of a Commercial BWR Late 1950’s Nuke plant and we have thousands of Lead Inserts embedded in the concrete that were used to mount gauges and unistrut to the walls.
.
In past decommissionings they were removed by:
1.
Pulling them out from t...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/3/2011 7:18:17 PM
Last Updated:
4/6/2011 1:04:07 PM
# of Solutions:
1
|
|
A leaking sump in a hot cell has resulted in soil contamination by fission products and transuranics. Are there similar contamination incidents at other DOE sites? If so, what soil volumes were involved and what remedial methods were deployed. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/23/2011 2:01:34 PM
Last Updated:
3/8/2011 3:40:19 PM
# of Solutions:
1
|
|
Is there any compact demolition equipment capable of efficiently working in a confined space (1-4 feet) that is able to remove high density reinforced concrete having a concrete strength of 5 kpsi to 7 kpsi? Does the device minimize airborne waste ge...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
6/9/2011 9:33:23 AM
Last Updated:
6/27/2011 5:21:29 PM
# of Solutions:
1
|
|
I am employed by LATA Environmental Service of Kentucky, LLC in the D&D Organization and have been asked to find an answer to the following question.
What is the standard industry practice for Asbestos Abatement and building demolition when the b...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
8/11/2011 9:57:02 AM
Last Updated:
8/15/2011 11:59:11 AM
# of Solutions:
1
|
|
I am looking for information gathered by Hanford's PFP on decontamination products such as Aspigel, Radpro or other products that were used during glovebox decommissioning. If possible, names and phone numbers for PFP personnel that can be directly c...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
1/26/2012 9:33:46 AM
Last Updated:
2/2/2012 1:18:09 PM
# of Solutions:
1
|
|
Years ago, (cant remember the year) at the Waste Management Conference (cant remember the city) I saw a robot that was climbing up the side of a truck that they said could be used underwater to clean a Spent Fuel Pool Liner. So the question is, who c...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
4/26/2012 11:25:27 AM
Last Updated:
5/3/2012 9:17:44 AM
# of Solutions:
1
|
|
I would like to know if there are some methods to decontaminate the wheels and axles of railcars used to transport casks loaded with radioactive components? Apparently, the cars were contaminated every time they entered the building, even though plas...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
12/18/2007 4:04:19 PM
Last Updated:
12/18/2007 4:22:00 PM
# of Solutions:
1
|
|
I would like to have more information on Tungsten Shielding. Vendors, prices etc. Could you help?...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
1/17/2008 1:44:25 PM
Last Updated:
3/2/2008 8:22:16 AM
# of Solutions:
1
|
|
I need to cut 2-inch pipe in a confined space with a 30 R/Hr hot spot located on the pipe. Can you suggest an appropiate cutting tool I can use? ...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
1/17/2008 2:00:31 PM
Last Updated:
3/2/2008 8:23:21 AM
# of Solutions:
1
|
|
I am looking for a means of attaching a radiological containment to a metal hose connection box? Can you help?...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
1/17/2008 2:23:15 PM
Last Updated:
3/2/2008 8:25:26 AM
# of Solutions:
1
|
|
What would be a good method to apply a fixative (Rust Doctor) inside 30" vent ducting connected to the B Plant vent system?...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
1/17/2008 2:41:54 PM
Last Updated:
3/2/2008 8:31:36 AM
# of Solutions:
1
|
|
An issue has been occurring in which there is buildup of metal chips and fines in the Side Dust Cover on the 7" Evolution Metal Cutting Saw. During cutting, the chips and fines are jamming up the workings of the saw blade guard and preventing it fro...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
1/17/2008 2:47:42 PM
Last Updated:
3/20/2008 7:52:40 AM
# of Solutions:
1
|
|
Request help finding a nibbler that would cut 1/2" carbon steel plate. We need to trim off a steel plate protruding from a concrete burial box....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
1/17/2008 6:13:21 PM
Last Updated:
3/20/2008 8:19:50 AM
# of Solutions:
1
|
|
I would like to receive some information on tools that could be use to cut through several layers of plastic when unwrapping material in gloveboxes. Our workers have been wearing Linemen's Gloves and using box knives to cut plastic bags and we are co...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
1/17/2008 6:49:37 PM
Last Updated:
3/2/2008 8:40:16 AM
# of Solutions:
1
|
|
We are going to coil a contaminated crane cable into a waste drum and I would like your advice on the best design for a ventilation scoop to hold near the cable as it is lowered into the drum....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
1/17/2008 7:10:49 PM
Last Updated:
3/20/2008 8:57:31 AM
# of Solutions:
1
|
|
I would like to get information regarding tools that would cut hydraulic hose without creating chips. We have several hoses that are inside a High Contamination area that need to be sized-reduced. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
1/23/2008 7:38:33 PM
Last Updated:
3/2/2008 8:45:19 AM
# of Solutions:
1
|
|
Request info on metal cutting circular saws. ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
1/23/2008 8:56:12 PM
Last Updated:
3/2/2008 8:47:51 AM
# of Solutions:
1
|
|
Request vendor information regarding vendors that could construct a neutron shield to install between TLD storage and a source....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
1/23/2008 9:17:35 PM
Last Updated:
3/2/2008 8:50:31 AM
# of Solutions:
1
|
|
I would like to get more information about non-destructive assay (NDA) We want to know the basics, how it works, and how we can benefit from this technique....
Category : Deactivation & Decommissioning > Characterization
|
Entered:
1/23/2008 9:47:45 PM
Last Updated:
3/2/2008 8:51:58 AM
# of Solutions:
1
|
|
I would like to have some information about Rock Stoppers for use with controlled vacuums....
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/6/2008 10:21:47 PM
Last Updated:
3/2/2008 8:54:42 AM
# of Solutions:
1
|
|
I would like to obtain shielding information showing the effect of different materials/protective clothing and beta radiation. We recently experienced radiological conditions where high-beta emitting isotopes were present in sufficient amounts to c...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/6/2008 10:50:16 PM
Last Updated:
3/2/2008 9:05:11 AM
# of Solutions:
1
|
|
Need advice for tar removal from the surface of 116-C tank in preparation for demolition....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/6/2008 11:01:28 PM
Last Updated:
3/2/2008 9:06:35 AM
# of Solutions:
1
|
|
I would like to have a list of most commonly used fixactive in the market for D&D related work.
...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/7/2008 12:15:03 AM
Last Updated:
2/28/2008 12:30:30 PM
# of Solutions:
1
|
|
At WRAP, we are working on 85 gallon over-packs that have been used for containing and venting the 55 gallon drum inside. We have to remove the stem tool, used for venting, between the 85 and 55 gallon drum lids. Can you suggest an appropiate glove ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/8/2008 11:59:17 AM
Last Updated:
3/2/2008 9:10:16 AM
# of Solutions:
1
|
|
I am looking for an overshoe or galoshes to be worn in the farms, with a non-skid surface on the bottom. Can you recommend any companies who sell this products?...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/12/2008 11:06:54 AM
Last Updated:
3/2/2008 9:13:04 AM
# of Solutions:
1
|
|
I am preparing for an upcoming job we have in a Tank Farms pit. We need to roughen the surface on the pit floor and contamination levels are very high. Are there any records on similar projects in the past? ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/12/2008 11:26:34 AM
Last Updated:
3/2/2008 9:14:23 AM
# of Solutions:
1
|
|
We are looking for a fixative that settles on the worker as an atomized mist, rather than a spray when exiting highly contaminated rooms....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/12/2008 11:39:54 AM
Last Updated:
3/2/2008 9:15:56 AM
# of Solutions:
1
|
|
I am looking for information on HEPA Filtered ventilation for core drilling through a concrete floor and removal of contaminated dirt during a sampling process. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/12/2008 11:56:23 AM
Last Updated:
3/2/2008 9:17:55 AM
# of Solutions:
1
|
|
I am looking for lightweight protective clothing to minimize heat stress at Tank Farms....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/12/2008 1:13:18 PM
Last Updated:
3/2/2008 9:24:56 AM
# of Solutions:
1
|
|
There is vent ducting in the 313 building that has Uranium contamination and piping above the ceiling in Building 3706 that has Pu. The Plan is to characterize the vent ducting before removal. Can you give any recommendations for this project?...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/12/2008 1:34:15 PM
Last Updated:
3/2/2008 9:27:05 AM
# of Solutions:
1
|
|
Team in Weapons Test Site in Las Vegas need advice to cocoon several contaminated railcars in a remote part of the Nevada desert rather than move them to location for dismantling. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/12/2008 1:52:41 PM
Last Updated:
2/28/2008 12:53:19 PM
# of Solutions:
1
|
|
FFTF need help in finding a tool that could be used to punch or drill holes in 6" stainless steel pipes. Two holes are needed in 110 closed end pipes for venting and draining. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/12/2008 2:01:29 PM
Last Updated:
2/28/2008 12:54:41 PM
# of Solutions:
1
|
|
I am having problems trying to decontaminate surfaces. Can you recommend any products that can help? ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/12/2008 2:19:10 PM
Last Updated:
3/2/2008 9:31:36 AM
# of Solutions:
1
|
|
I am looking for a band saw I can use to cut up a 12" thick Control Rod Drive Mechanism. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/12/2008 2:28:42 PM
Last Updated:
2/28/2008 1:12:11 PM
# of Solutions:
1
|
|
Ground water RadCon needs help in looking for ways to introduce a glove in a sleeve to take smears on some crib work at U-Plant.
...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/12/2008 2:35:28 PM
Last Updated:
3/20/2008 8:56:04 AM
# of Solutions:
1
|
|
What is the shielding effectiveness for beta radiation if workers wear safety glasses or face shields? ...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/12/2008 2:51:14 PM
Last Updated:
3/2/2008 9:36:12 AM
# of Solutions:
1
|
|
I am looking for information on what other sites have done to seal penetrations in concrete slabs left after D&D work is complete. I need to seal penetrations that will be exposed to the environment and the seal has to last for at least 20 years. The...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/12/2008 3:05:02 PM
Last Updated:
3/2/2008 9:42:19 AM
# of Solutions:
1
|
|
I am requesting information on how items are transferred out of glovebags. We have purchased a "doghouse" glovebag for handling radioactive drugs and the transfer sleeve is too large (18" diameter....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/12/2008 3:16:48 PM
Last Updated:
3/2/2008 9:44:53 AM
# of Solutions:
1
|
|
I am having problems pumping out debris from a tank. The plan is to pump out the debris in a slurry through a hose that will have to be draped over the worker's shoulder however, high gamma radiation levels may be present. In order to reduce the w...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/12/2008 3:30:30 PM
Last Updated:
2/28/2008 2:04:14 PM
# of Solutions:
1
|
|
Do you know of a source of information on Technetium99...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/12/2008 3:40:28 PM
Last Updated:
2/28/2008 2:04:48 PM
# of Solutions:
1
|
|
I am looking for information on who makes portable HEPA filtered vent units that are rated at 25,000-30,000 cfm or greater. We are going to attach the unit to buildings in the 300 Area undergoing D&D to draw a slight negative pressure on each buildi...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/12/2008 3:46:37 PM
Last Updated:
3/2/2008 11:36:24 AM
# of Solutions:
1
|
|
Can you suggest a good source of information on protective coatings?...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/12/2008 3:57:03 PM
Last Updated:
2/28/2008 2:05:23 PM
# of Solutions:
1
|
|
I am looking for a source of pads that could be used for decontamination...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/12/2008 4:09:14 PM
Last Updated:
2/28/2008 2:06:02 PM
# of Solutions:
1
|
|
WRAP operations is looking for a cutting tool that would shear the bolt on a drum lid ring in the process line. There were some special requirements, such as needing to have a thin cutting blade, < 3/8", and light enough to allow workers to handle t...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/12/2008 4:18:13 PM
Last Updated:
3/2/2008 9:50:56 AM
# of Solutions:
1
|
|
INEEL needed advice on changing highly contaminated glove box windows. Three windows were broken when a waste drum was dropped inside the glove box. ...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/12/2008 4:21:31 PM
Last Updated:
3/2/2008 9:58:23 AM
# of Solutions:
1
|
|
Please provide information on actions that could be taken to improve working conditions in Tank Farms during the warm summer months?...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/12/2008 4:26:50 PM
Last Updated:
3/2/2008 10:06:24 AM
# of Solutions:
1
|
|
WCH Radcon needs information on an asbestos encapsulant. We are considering using A-B-C Asbestos Binding Compound as a fixative for radioactive contamination...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/12/2008 4:36:35 PM
Last Updated:
3/2/2008 10:08:07 AM
# of Solutions:
1
|
|
FFTF needs to reduce the size of a boundary around a Californium source they have in storage. The source container is similar to a 5-gallon bucket. They prefer not using any shielding with water. Can you give any suggestions? ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/12/2008 4:42:53 PM
Last Updated:
2/28/2008 2:17:47 PM
# of Solutions:
1
|
|
We are working on the application of expandable foam in a ten foot section of 3' diameter duct that is located underground from the 232-Z building at PFP. The rest of the duct will be filled with grout but we want the last ten feet that will press ag...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/13/2008 11:06:38 AM
Last Updated:
2/28/2008 2:19:11 PM
# of Solutions:
1
|
|
I am looking for information on changing out the HEPA filter on a Euroclean UZ-948 HEPA filtered vacuum cleaner. We have a "new" HEPA filter but it has been stored in a connex box for several years instead of an approved climate-controlled storage a...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/13/2008 11:19:06 AM
Last Updated:
3/2/2008 10:12:47 AM
# of Solutions:
1
|
|
I have a question on obtaining a glovebag to inspect containers of Pu recovered from a burial ground North of the 300 Area. ...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/13/2008 11:28:36 AM
Last Updated:
2/28/2008 2:24:35 PM
# of Solutions:
1
|
|
Does any containment manufacturer sell a standard glovebag made for changing the lids on waste drums to a new vented lid?...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/13/2008 11:47:13 AM
Last Updated:
2/28/2008 2:25:39 PM
# of Solutions:
1
|
|
Which vendors sell solar powered air samplers?...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/13/2008 12:16:24 PM
Last Updated:
2/28/2008 2:26:04 PM
# of Solutions:
1
|
|
I need either a hydraulic or battery powered tool to cut piping in the 300 area. Can you provide me with some information?...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/13/2008 12:34:45 PM
Last Updated:
2/28/2008 2:26:41 PM
# of Solutions:
1
|
|
We have a problem with "Fibercast" piping. The piping is made with fiberglass and one flange has fixed contamination that becomes removable (loose) every time it rains. Presently, the flange is covered with a large plastic sleeve. What can we do?...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/13/2008 12:42:15 PM
Last Updated:
2/28/2008 2:27:27 PM
# of Solutions:
1
|
|
I am looking for a measuring tool that can measure pipe wall thickness without removing insulation....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/13/2008 12:46:56 PM
Last Updated:
3/2/2008 10:23:21 AM
# of Solutions:
1
|
|
A medical facility needs recommendation on sealing lead bricks to reduce the chance that workers would transfer lead particles from the bricks into their body when they handled them bare-handed. ...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/13/2008 12:53:39 PM
Last Updated:
2/28/2008 2:29:08 PM
# of Solutions:
1
|
|
I need information on HEPA filtered ventilation units I can use as a backup system during TRU waste retrieval operations....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/13/2008 1:55:49 PM
Last Updated:
2/28/2008 2:30:44 PM
# of Solutions:
1
|
|
Do you know a good source of information for digging up burial grounds or handling waste containers? ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/13/2008 2:34:14 PM
Last Updated:
3/2/2008 10:27:51 AM
# of Solutions:
1
|
|
Where can I find articles associated with radioactive waste management?...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/13/2008 2:43:39 PM
Last Updated:
3/2/2008 10:29:54 AM
# of Solutions:
1
|
|
We are planning on pouring concrete slurry into a 1000 gallon tank, the concrete vendor is concerned about damaging the paper HEPA filter attached to the tank to filter displaced air during the slurring operation. The vendor suggested an in line cha...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/15/2008 1:11:42 PM
Last Updated:
3/2/2008 10:31:31 AM
# of Solutions:
1
|
|
We are looking for suppliers of large leather gloves. In the past, during repacking in the Canyon, the workers wore multiple layers of PPE glove with a #12 leather glove on the outside. Recently, the leather gloves we found have been smaller than t...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/15/2008 1:24:20 PM
Last Updated:
3/2/2008 10:39:15 AM
# of Solutions:
1
|
|
We currently use handtools to decontaminate the buckets of large excavators which are used to collect contaminated dirt and debris that have been "fixed" with a gooey fixative. This method is difficult and very time consuming. Can you suggest a bette...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/15/2008 1:57:16 PM
Last Updated:
2/28/2008 2:37:05 PM
# of Solutions:
1
|
|
Can you provide recommendations concerning the venting and shielding of 55 gallon drums that will contain HEPA filters removed from their hot cells? ...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/16/2008 9:29:06 AM
Last Updated:
3/2/2008 10:44:52 AM
# of Solutions:
1
|
|
Do you have recommendations concerning the removal of a large lead cave that may be contaminated due to an americium spill that occurred years ago. The cave contains many lead bricks that have to be removed one-at-a-time....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/16/2008 9:38:04 AM
Last Updated:
2/28/2008 2:38:31 PM
# of Solutions:
1
|
|
I am looking for a method to remove multiple layers of paint inside glove boxes in order to reduce the source term. Chemical removal will not work because the painted surface has a coat of RadPro covering the paint. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/16/2008 9:48:50 AM
Last Updated:
2/28/2008 2:39:08 PM
# of Solutions:
1
|
|
I am looking at different fixatives that could be used to capture contamination from residual sodium that leaked from some bagging around stainless steel assemblies. ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/16/2008 9:58:33 AM
Last Updated:
3/2/2008 10:48:59 AM
# of Solutions:
1
|
|
Can you provide information on fixing contamination inside tanks? ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/16/2008 10:06:25 AM
Last Updated:
3/2/2008 10:52:01 AM
# of Solutions:
1
|
|
What is a safe way to remove a HEPA filter housing from a tank riser....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/16/2008 10:16:40 AM
Last Updated:
3/2/2008 10:53:22 AM
# of Solutions:
1
|
|
Need a recommendation on decontaminating a Uranium facility concrete floor with deeply imbedded contamination....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/16/2008 10:49:38 AM
Last Updated:
3/2/2008 10:56:00 AM
# of Solutions:
1
|
|
We are raising components into a sleeve, turning the component to twist the sleeve and then applying tape to the twisted portion before the sleeve is cut with electrical cable cutters. Then We fold the hanging sleeve up around the component so it lo...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/16/2008 11:05:01 AM
Last Updated:
3/20/2008 9:01:21 AM
# of Solutions:
1
|
|
We need to survey a vault below the Building 325 Hot Cell can you suggest an appropiate camara?...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/16/2008 11:22:18 AM
Last Updated:
2/28/2008 3:45:11 PM
# of Solutions:
1
|
|
I need suggestions concerning the removal of a tank at the San Onofre reactor near San Diego. Inner liner of the tank is held in place with "L" shaped metal brackets that are spot welded. They wanted to know whether the ALARA Center had tools that ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/16/2008 11:45:57 AM
Last Updated:
2/28/2008 3:46:00 PM
# of Solutions:
1
|
|
What are the steps necessary to convert a 40' long Conex Container into a portable radioactive work facility. We are looking for a location that could be used to decontaminate cameras, cables, tools, and small equipment....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/18/2008 9:39:16 PM
Last Updated:
3/2/2008 11:01:10 AM
# of Solutions:
1
|
|
We would like to have information concerning a radiation resistant sealant that can be used to seal glove box windows...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/18/2008 10:14:46 PM
Last Updated:
2/28/2008 4:00:40 PM
# of Solutions:
1
|
|
We are looking for suggestions on ways to hold samples and reduce worker dose....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/18/2008 10:35:55 PM
Last Updated:
3/2/2008 11:05:03 AM
# of Solutions:
1
|
|
I would like to recieve information about disposable protective clothing for potential use on an upcoming job....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/18/2008 10:44:24 PM
Last Updated:
2/28/2008 4:02:36 PM
# of Solutions:
1
|
|
We are looking for companies that specialize in shielding of different types of radioactivity, like Gamma, Neutrons and beta radiation...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/18/2008 11:01:36 PM
Last Updated:
3/2/2008 11:07:08 AM
# of Solutions:
1
|
|
I am looking for a tool with negative vent port capabilities (shrouded) to grind on some hazardous material....
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/18/2008 11:28:05 PM
Last Updated:
3/2/2008 11:08:59 AM
# of Solutions:
1
|
|
I am looking for strippable paint to decontiminate pump impellers.
Also I am looking for a better tape that will adhere to the Frham Tech II PPE and the PAPR bib.
...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/18/2008 11:39:59 PM
Last Updated:
3/2/2008 11:12:51 AM
# of Solutions:
1
|
|
I am looking for foam leaded temporary shielding. could you please help me?...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/18/2008 11:57:30 PM
Last Updated:
3/20/2008 9:06:26 AM
# of Solutions:
1
|
|
I am looking for lead blanket shielding, especially longer blankets, and glove bags for work on the end of a transfer cask....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/19/2008 12:14:45 AM
Last Updated:
3/2/2008 11:17:48 AM
# of Solutions:
1
|
|
I would like to obtain information concerning methods to decontaminate the outside of 1300+, fifty-five gallon waste drums that read ~100 Rem/h that are located behind a 22" shield wall....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/19/2008 12:30:51 AM
Last Updated:
3/2/2008 11:20:06 AM
# of Solutions:
1
|
|
Where can I find a list of DOE Technical Standards?...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/19/2008 12:40:02 AM
Last Updated:
2/28/2008 4:23:13 PM
# of Solutions:
1
|
|
I have some questions about the Devcon Patch product. How does it work? How much does it cost? As I recall the patches are about $30.00 each...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/19/2008 12:47:15 AM
Last Updated:
3/2/2008 11:22:06 AM
# of Solutions:
1
|
|
I would like info about a product to bond stainless steel. I am interested in securing barrier material between a sample assembly and glove box. That area could contact nitric acid, aluminum oxide or Pu 239...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/19/2008 1:22:21 AM
Last Updated:
3/2/2008 11:23:35 AM
# of Solutions:
1
|
|
I have a problem concerning a 250 mr/hr hot spot on the bottom of a tank. The spot is about the size of a dime. My plan is to reach down through the man way and remove it using a HEPA filtered vacuum cleaner. Depending on the radiation level, the va...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/19/2008 1:36:06 AM
Last Updated:
2/28/2008 4:25:49 PM
# of Solutions:
1
|
|
I would like to have information about portable or hand held line of non-intrusive ultrasonic clamp-on flow meters...
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/19/2008 1:45:55 AM
Last Updated:
2/28/2008 4:26:24 PM
# of Solutions:
1
|
|
Video equipment for monitoring of sludge transfer....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/19/2008 12:09:30 PM
Last Updated:
3/20/2008 9:11:53 AM
# of Solutions:
1
|
|
Seeking an inexpensive containment method for personnel egressing from a burial ground....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/19/2008 12:28:51 PM
Last Updated:
3/2/2008 11:29:13 AM
# of Solutions:
1
|
|
Searching for information on HEPA vacuum cleaners and HEPA filtered exhauster....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/19/2008 1:10:19 PM
Last Updated:
3/20/2008 8:10:58 AM
# of Solutions:
1
|
|
Looking for information on tools for cutting a carbon steel sample riser pipe close to where it exits a concrete slab....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/19/2008 1:21:04 PM
Last Updated:
2/27/2008 4:44:40 PM
# of Solutions:
1
|
|
Requesting assistance with removing 250' of contaminated PVC piping at life Sciences Lab-2 in North Richland. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/19/2008 2:27:30 PM
Last Updated:
3/2/2008 11:40:21 AM
# of Solutions:
1
|
|
Requesting information on Vendors that have experience on entering ventilation ducting with equipment (robotics) to gather information to characterize the residual material in the duct....
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/19/2008 3:32:14 PM
Last Updated:
3/2/2008 11:42:31 AM
# of Solutions:
1
|
|
A question arose this week on placement of a muffler on an HEPA filtered ventilation exhauster. Inlet or outlet side of the unit?...
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/19/2008 3:47:46 PM
Last Updated:
3/2/2008 11:43:48 AM
# of Solutions:
1
|
|
Facility located in downtown Richland and was used years ago for personnel decontamination near Kadlac Hospital. Looking for information on cutting contaminated piping 24" to 36" in diameter. ...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/20/2008 6:20:33 AM
Last Updated:
3/2/2008 11:45:47 AM
# of Solutions:
1
|
|
Looking for a pumping system to remove liquid and suspended solids from a tank. Need to lift the liquid 29 feet plus an additional 10 feet to a tank....
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
2/20/2008 6:34:47 AM
Last Updated:
3/2/2008 11:48:02 AM
# of Solutions:
1
|
|
Looking for underwater tools to cut 4" piping and angle iron....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/20/2008 6:41:26 AM
Last Updated:
3/2/2008 11:50:30 AM
# of Solutions:
1
|
|
Looking for information for cutting out the pencil tank piping and stainless steel support members....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/20/2008 6:55:51 AM
Last Updated:
3/26/2008 9:40:54 AM
# of Solutions:
1
|
|
Looking for advice on the radiological controls for hot tapping a 4" diameter pipe....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/20/2008 7:34:10 AM
Last Updated:
3/2/2008 8:08:40 AM
# of Solutions:
1
|
|
Looking for a glovebag that can be used for pipe cutting and welding in Tank Farms....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/20/2008 8:14:54 AM
Last Updated:
2/27/2008 4:45:53 PM
# of Solutions:
1
|
|
Tank farms need a cutting tool that can lower about 12' down a pipe and cut an internal PVC liner without cutting the pipe....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/20/2008 8:29:26 AM
Last Updated:
2/27/2008 4:46:35 PM
# of Solutions:
1
|
|
Looking for a tool to remove liquid from plastic bags without opening the bags....
Category : Deactivation & Decommissioning > Characterization
|
Entered:
2/20/2008 8:59:05 AM
Last Updated:
3/2/2008 8:12:41 AM
# of Solutions:
1
|
|
Requesting info on tools that can be used to size-reduce 6" Schedule 40 piping....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/20/2008 9:17:26 AM
Last Updated:
3/2/2008 8:15:34 AM
# of Solutions:
1
|
|
Looking for better shoe covers in areas that have high contamination levels....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
2/20/2008 11:02:32 AM
Last Updated:
3/2/2008 8:17:31 AM
# of Solutions:
1
|
|
Need a shear to cut 1.5" carbon steel piping....
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
2/20/2008 11:29:02 AM
Last Updated:
2/28/2008 11:13:41 AM
# of Solutions:
1
|
|
Decontaminating a 500 sq ft area in a PNNL facility. Require fixatives that can be used to cover this contamination before workers entered the room. ...
Category : Deactivation & Decommissioning > Decontamination
|
Entered:
3/11/2008 1:02:08 AM
Last Updated:
3/19/2008 1:05:27 PM
# of Solutions:
1
|
|
Looking for tooling to scabble concrete in a scrubber cell. Want to remove just the top 1/4 inch of material. Requesting information on available tooling other than Pentek Inc (www.pentekusa.com).
...
Category : Deactivation & Decommissioning > Dismantlement & Material Disposition
|
Entered:
3/10/2008 12:15:28 PM
Last Updated:
3/19/2008 1:12:32 PM
# of Solutions:
1
|
|
Looking for information regarding an enclosure for the sample trucks during work....
Category : Deactivation & Decommissioning > Worker Safety
|
Entered:
3/10/2008 12:29:43 PM
Last Updated:
3/19/2008 1:16:45 PM
# of Solutions:
1
|
|