Demonstration Name:Building 68 at the FEMP Site | Demonstrated on: 9/16/1997
Demonstration Site: Fernald Environmental Management Project
Demo Objective
The main objective of the demonstration was to assess heat stress management using the PICS as an alternative to the baseline of limiting stay times and using cool-down rooms. This investigation assessed the PICS based on its performance, relative to the baseline stay times, in achieving the following demonstration objectives:
· increased worker stay time,
· increased work productivity,
· reduced costs,
· increased worker well being and comfort,
· decreased consumption of PPE, and
· reduction in overall D&D schedules
Demo Results
The PICS allowed the workers to maintain a comfortable body temperature.
Worker stay times were greatly increased as a result of wearing the PICS. On the days of the
demonstration where work area temperatures exceeded 100ºF, stay times were more than four
times longer with the PICS than the baseline.
The higher the temperature in the work area, the greater the increase in stay times and the
greater the productivity increase as a result of the PICS. Significant advantages occur when the
work area temperature is over 85º Fahrenheit (F).
The amount of PPE required for a specific task affects the productivity gain with the PICS.
Significant advantages occur with the PICS when impermeable PPE and/or respirators are
required for a task.
Workers preferred the PICS over ice vests (not evaluated in this demonstration) and over not
wearing any cooling devices. They found the PICS more comfortable, less fatiguing, and felt it
allowed them to perform more work. One worker also commented that he felt his energy level
was much greater with the PICS.
Based on the stay times observed during the demonstration , the cost savings resulting from the use of the PICS are $47/hour per two-person crew (a 39% savings) for work area temperatures between 70 and 85ºF and $159/crew-hour (a 66% savings) for temperatures greater than 85ºF. Cost savings are based on D&D labor, equipment, and disposable PPE. The pay-back period (time for cost recovery for buying the system) for the PICS is 30 crew-hours of work at temperatures between 70 and 85ºF and only 9 crew-hours at temperatures greater than 85ºF.
Building 68 at the FEMP site
The PICS allowed the workers to maintain a comfortable body temperature.
Worker stay times were greatly increased as a result of wearing the PICS. On the days of the
demonstration where work area temperatures exceeded 100ºF, stay times were more than four
times longer with the PICS than the baseline.
The higher the temperature in the work area, the greater the increase in stay times and the
greater the productivity increase as a result of the PICS. Significant advantages occur when the
work area temperature is over 85º Fahrenheit (F).
The amount of PPE required for a specific task affects the productivity gain with the PICS.
Significant advantages occur with the PICS when impermeable PPE and/or respirators are
required for a task.
Workers preferred the PICS over ice vests (not evaluated in this demonstration) and over not
wearing any cooling devices. They found the PICS more comfortable, less fatiguing, and felt it
allowed them to perform more work. One worker also commented that he felt his energy level
was much greater with the PICS.
Based on the stay times observed during the demonstration , the cost savings resulting from the use of the PICS are $47/hour per two-person crew (a 39% savings) for work area temperatures between 70 and 85ºF and $159/crew-hour (a 66% savings) for temperatures greater than 85ºF. Cost savings are based on D&D labor, equipment, and disposable PPE. The pay-back period (time for cost recovery for buying the system) for the PICS is 30 crew-hours of work at temperatures between 70 and 85ºF and only 9 crew-hours at temperatures greater than 85ºF.
Building 68 at the FEMP site
The PICS allowed the workers to maintain a comfortable body temperature.
Worker stay times were greatly increased as a result of wearing the PICS. On the days of the
demonstration where work area temperatures exceeded 100ºF, stay times were more than four
times longer with the PICS than the baseline.
The higher the temperature in the work area, the greater the increase in stay times and the
greater the productivity increase as a result of the PICS. Significant advantages occur when the
work area temperature is over 85º Fahrenheit (F).
The amount of PPE required for a specific task affects the productivity gain with the PICS.
Significant advantages occur with the PICS when impermeable PPE and/or respirators are
required for a task.
Workers preferred the PICS over ice vests (not evaluated in this demonstration) and over not
wearing any cooling devices. They found the PICS more comfortable, less fatiguing, and felt it
allowed them to perform more work. One worker also commented that he felt his energy level
was much greater with the PICS.
Based on the stay times observed during the demonstration , the cost savings resulting from the use of the PICS are $47/hour per two-person crew (a 39% savings) for work area temperatures between 70 and 85ºF and $159/crew-hour (a 66% savings) for temperatures greater than 85ºF. Cost savings are based on D&D labor, equipment, and disposable PPE. The pay-back period (time for cost recovery for buying the system) for the PICS is 30 crew-hours of work at temperatures between 70 and 85ºF and only 9 crew-hours at temperatures greater than 85ºF.
Building 68 at the FEMP site
The PICS allowed the workers to maintain a comfortable body temperature.
Worker stay times were greatly increased as a result of wearing the PICS. On the days of the demonstration where work area temperatures exceeded 100ºF, stay times were more than four times longer with the PICS than the baseline.
The higher the temperature in the work area, the greater the increase in stay times and the greater the productivity increase as a result of the PICS. Significant advantages occur when the work area temperature is over 85º Fahrenheit (F). The amount of PPE required for a specific task affects the productivity gain with the PICS.
Significant advantages occur with the PICS when impermeable PPE and/or respirators are required for a task.
Workers preferred the PICS over ice vests (not evaluated in this demonstration) and over not wearing any cooling devices. They found the PICS more comfortable, less fatiguing, and felt it allowed them to perform more work. One worker also commented that he felt his energy level was much greater with the PICS.
Based on the stay times observed during the demonstration, the cost savings resulting from the use of the PICS are $47/hour per two-person crew (a 39% savings) for work area temperatures between 70 and 85ºF and $159/crew-hour (a 66% savings) for temperatures greater than 85ºF. Cost savings are based on D&D labor, equipment, and disposable PPE. The pay-back period (time for cost recovery for buying the system) for the PICS is 30 crew-hours of work at temperatures between 70 and 85ºF and only 9 crew-hours at temperatures greater than 85ºF.
Pictures